CANTILEVER HOLELESS ADVANTAGES/DISADVANTAGES
Design utilizing a single hydraulic jack and installed on the pit floor. The platform is supported by a cantilevered car frame with the jack and rails located on one side of the hoistway. Single stage jacks can accommodate approximately 12'-6" of travel. Two stage telescopic jacks can accommodate approximately 23'-0" of travel. Travel may dictate the pit and overhead.
Advantages:
- Allows for front, rear, and side openings
- Allows for glass walls on sides where equipment is not located
- Rail bracket attachment only on one wall
- Jack hole is not required - Eliminates cost for drilling and reduces the risk of oil contamination
Disadvantages:
- Larger hoistway size required
- Platform depth limited due to cantilever design
- Only available with low capacity elevators (2500 Lbs or less)
- Additional pit and overhead may be required with higher travels
- Material costs are typically higher compared to an in-ground application
 These specifications cover all products and will require editing to meet your project requirements.
Cemcolift can provide standard sizes (as shown in chart below) as well as Non-Standard or Custom sized elevators. Please contact us to design a Non-Standard or Custom sized elevator. |
CANTILEVER HOLELESS DRAWING DOWNLOADS
|
| DWG # |
CAPACITY |
OPENINGS |
TRAVEL UP TO |
INSIDE CAB |
PLAN VIEW DRAWING |
SECTION VIEW & MACHINE ROOM DRAWINGS |
| CH1 |
2000 |
Front |
12'-6'' |
5'-8'' W x 4'-3'' D |
DWG/PDF
|
DWG/PDF
|
| CH2 |
2500 |
Front |
12'-6'' |
6'-8'' W x 4'-3'' D |
DWG/PDF
|
DWG/PDF
|
| CH3 |
2500 |
Front |
12'-6'' |
5'-0'' W x 5'-0'' D |
DWG/PDF
|
DWG/PDF
|
| CH4 |
2000 |
Front & Rear |
12'-6'' |
4'-3'' W x 5'-8'' D |
DWG/PDF
|
DWG/PDF
|
| CH5 |
2500 |
Front & Rear |
12'-6'' |
4'-6'' W x 6'-8'' D |
DWG/PDF
|
DWG/PDF
|
| CH6 |
2500 |
Front & Rear |
12'-6'' |
5'-0'' W x 5'-0'' D |
DWG/PDF
|
DWG/PDF
|
| CH7 |
2000 |
Front & Side |
12'-6'' |
5'-8'' W x 4'-3'' D |
DWG/PDF
|
DWG/PDF
|
| CH8 |
2500 |
Front & Side |
12'-6'' |
6'-8'' W x 4'-3'' D |
DWG/PDF
|
DWG/PDF
|
| CH9 |
2500 |
Front & Side |
12'-6'' |
5'-0'' W x 5'-0'' D |
DWG/PDF
|
DWG/PDF
|
|
 |